Tüm Kategoriler

Temasa geçin

Kule UPS AC208V/AC220V/AC240V

Ev >  Ürünler >  UPS >  Kule UPS AC208V/AC220V/AC240V

UPS Tower UPS AC208V AC220V AC240V
UPS Tower UPS AC208V AC220V AC240V
UPS Tower UPS AC208V AC220V AC240V
UPS Tower UPS AC208V AC220V AC240V
UPS Tower UPS AC208V AC220V AC240V
UPS Tower UPS AC208V AC220V AC240V
UPS Tower UPS AC208V AC220V AC240V
UPS Tower UPS AC208V AC220V AC240V
UPS Tower UPS AC208V AC220V AC240V
UPS Tower UPS AC208V AC220V AC240V
UPS Tower UPS AC208V AC220V AC240V
UPS Tower UPS AC208V AC220V AC240V
UPS Tower UPS AC208V AC220V AC240V
UPS Tower UPS AC208V AC220V AC240V

UPS Kule UPS AC208V AC220V AC240V

Model : 1K / 1KS / 2K / 2KS / 3K / 3KS

 

Modeli : 6K / 6KS / 10K / 10KS


  • Özellik
  • Parametre
  • Temasa geçin
  • Indirme

Uygulama


 

Kritik ekipmanlarınıza güvenilir ve kesintisiz güç kaynağı sağlayan son teknoloji bir güç çözümü olan sağlam UPS Tower'ımızla tanışın. Bu UPS Kulesi hassas bir şekilde üretilmiştir ve çok çeşitli giriş voltajlarını idare edecek şekilde tasarlanmıştır, bu da onu AC 208V, AC 220V ve AC 240V ile çalışan sistemler için mükemmel bir uyum sağlar.

Özünde çok yönlülük ile tasarlanan UPS Tower, çeşitli elektrik sistemlerine sorunsuz bir şekilde entegre olmasını sağlayan olağanüstü uyumluluğa sahiptir. İster 208V, ister 220V veya 240V bir ortamda çalışıyor olun, bu UPS Kulesi, ekipmanınızın sorunsuz çalışmasını sağlamak için kararlı ve sürekli bir güç kaynağı sağlar.

UPS Kulemizin geniş voltaj uyumluluğu, maksimum esneklik ve güvenilirlik sağlar. Nerede olursanız olun veya tesisiniz hangi voltaj standardını kullanırsa kullansın, UPS Kulemiz gerekli güç yedeğini uyarlama ve sağlama yeteneğine sahiptir. Bu, kritik ekipmanınızın elektrik kesintileri veya voltaj dalgalanmaları sırasında çalışır durumda kalmasını sağlayarak veri kaybı veya ekipman hasarı riskini en aza indirir.

 


Özellik


  •  

 

Sıfır Transfer süresi:Gerçek Çift Dönüşümlü Çevrimiçi UPS, Görev Açısından Kritik Ekipmanları Çok Çeşitli Güç Kalitesi Sorunlarından En Kapsamlı Şekilde Koruyun
DSP Dijital Kontrol Tabanlı:Gelişmiş DSP tabanlı dijital kontrol, yüksek giriş Güç faktörü, düşük bozulma yüksek performans sağlar, mükemmel sinüs dalgası AC güç kaynağı ile yükü besler
Ultra Geniş Giriş Şebeke aralığı:Elektrikli ortamla ultra ile güçlü uyumlu, 90V ~ 300V, 40 ~ 70Hz ultra geniş aralıklı şebeke ile iyi kalın, pil deşarjını  önemli ölçüde azaltın, pil ömrünü uzatın
En İyi Yükleme Kapasitesi:0,9'a kadar Çıkış Gücü Faktörü, 50/60 Hz Otomatik olarak uyarlanan, seçilebilir voltaj, her türlü uygulamaya mükemmel uyum sağlar
Jeneratör Uyumlu:Çok çeşitli Jeneratör ile çalışabilme, Jeneratörden dalgalanma ve gürültüyü izole edebilme, kullanıcı ekipmanına istikrarlı ve temiz güç kaynağı sağlar.
Yüksek Giriş güç faktörü:Dijital kontrollü  PFC Teknolojisi sayesinde, >0.99 giriş güç faktörü, güç kirliliğini etkili bir şekilde önler, müşteri için enerji giderinden tasarruf sağlar
Güvenilir tasarım:Güçlü Cam elyaf taban (FR4) çift taraflı PCB ile yapılmış, geniş açıklıklı bileşene sahip şirket, zorlu ortamlarda güvenilirliği büyük ölçüde artırır, İyi tasarlanmış havalandırma ve uygun kaplama, toz birikimini önler, korozyona karşı direnci artırır
Özelleştirmeye açık:Güçlü kontrolör ve açık mimariye dayanan ürün, otomatik sistem veya akıllı denetim sisteminin entegrasyon ihtiyacını karşılayacak şekilde özelleştirilebilir

 

SSS


 

Şarj çözümünüz var mı ? 
A:Yes, BVT suitable for battery charging usage. In this application, our rectifier system is widely used for N+1 power supply and battery charging system management.

Does the product support the SNMP function?
A:Yes, 90% BVT product support SNMP. And all product built-in RS485 communication for standard. 

What is RS485?
A:RS485 is a communication interface, support real-time data communication function, and can use the monitoring software to monitor and control the working condition of the inverter power supply in a real-time manner. supply.(Optional)

Can the inverter adapt to high temperature and operate stably?
A:BVT supports a maximum temperature of -20℃~60℃, and the stable operation is unchanged. If you configure air conditioning cooling in a high temperature environment, the product life will be increased

Can the inverter power supply be used on the plane?
A:Currently not supported, because the height problem will affect the operation of the inverter and fail. Haibo ≥ 2000 meters, the inverter will fail and not work

How about the inverter load?
A:Super overload capacity, can withstand full load startup, with bypass switch, can switch to bypass power supply when overloaded

How about high frequency inverter power supply noise?
A:≤55dB

Can I choose the mains mode for my inverter power supply?
A:Yes, BVT inverter support AC main power supply and DC main power supply, 2 modes can be selected flexibly, and the mode can be changed through the LCD panel or the communication background software

What will causes Power failure and what can be done to resolve?
A: Check whether the positive and negative poles are reversed, and reconnect after confirming. If it cannot be turned on, please return the power supply back to BVT for inspection & repairing

What are the protection functions of the inverter power supply?
A:Input under-voltage protection, anti-DC input reverse connection, buffer protection, over-voltage protection, overload protection, short-circuit protection, over-temperature protection, temperature-controlled fan, etc.

 


Parametre tablosu



Kule 1~3K Çevrimiçi UPS Veri Sayfası(220V PF0.9 IEC62040)

 

Model1K1 KS2K2KS (2KS)3K3KS (3KS)
KapasiteVA/W1kVA/900W2kVA/1.8kW3kVA / 2.7kW
TopolojiÇift Dönüşümlü Online UPS
AşamaTek Fazlı Giriş Tek Fazlı Çıkış
Şebeke GirişiKablolamaL / N + PE
Anma gerilimi208/220/230 / 240VAC
Voltaj Aralığı 90 ~ 300 VAC
Frekans aralığı40Hz ~ 70Hz
Giriş Güç Faktörü≥0,99
AC ÇıkışıKablolamaL / N + PE
Çıkış Voltajı208/220/230 / 240VAC
Voltaj Regülasyonu±1%
Çıkış Frekansı50/60±4Hz (Senkronizasyon Modu) / 50/60Hz±0.1% (Serbest Çalışma)
Dalga biçimiSaf Sinüs Dalgası
Bozulma
(THDV%)
<2%(Linear Load)
<7%(None-Linear Load)
Aşırı yük
 capability
% 1Min@105 ~% 125 Nominal Yük
30Sec.@125%~150%Rated Load
0.5Sec.@>150%Rated Load
RandımanÇizgi modu88%89%90%
Pil Modu86%87%88%
Pil
&
Charge
Nominal Akü Voltajı (1)24VDC (24VDC)
Internal
36VDC (36VDC)
External
48VDC (48VDC)
Internal
72VDC (72VDC)
External
72VDC (72VDC)
Internal
72VDC (72VDC)
External
Pil Kapasitesi7AHx2 adetHarici Batarya Bağlıdır 7AHx4 adetHarici Batarya Bağlıdır 7AHx6 adetHarici Batarya Bağlıdır
Yedekleme Süresi>6 dakika @ Yarım Yük>6 dakika @ Yarım Yük>6 dakika @ Yarım Yük
Şarj AkımıDahili Bataryalı Standart Model: 1A
Long Backup Time Model :4A
Sipariş için isteğe bağlı yapılandırma
  1. Standart model için harici pil modülü konektörü
  2. Pil Kapasitesi: 7AH / 9AH
  3. Pil Miktarı (2/4 / 6 adet) veya (3/6 / 6 adet)
FizikselŞasi StiliKule
Kule Ölçüsü1KS, 1K: 145 (G) X220 (Y) x318 (D) mm
 2KS, 2K, 3K, 3KS: 190(W) x 318(H) x 368(D)mm
Ağırlık (kg)8.44.716.210.521.212.0
HMILCD EKRANGiriş Şebeke Voltajı, Frekans, Yük seviyesi, Çalışma Modu, Sağlık Durumu
Standart
Communication Interface
1.RS232 BAĞLANTI NOKTASI  2.EPO / ROO Bağlantı Noktası  3.Akıllı Yuva  4.USB Kartı (HID değil)
Opsiyonel Genişletme Kartı
  1. NetWork Kartı:  UPS'i Akıllı Telefon APP, Web sayfası,  PC Monitör Yazılımı, Destek Sunucusu / NAS kapatma ile uzaktan izlemek için SNMP / TCP / IP desteği
  2. RS485-MODBUS Kartı,  LAN (TCP IP) -MODBUS Kartı,
  3. Mini AS400 Röle Kartı  
Çalışma Ortamı
Endurance
Sıcaklık aralığı-10 ~ 50 °C
Bağıl nem% 0-98 (Yoğuşmasız)
Akustik Gürültü<55dB @ 1 meters


Kule 6~10K Çevrimiçi UPS Veri Sayfası(220V PF0.9 IEC62040)

 

Model6K6 Bin Saniye10K10 Bin Saniye
KapasiteVA/W6kVA/5.4kW10kVA/9kW
TopolojiÇift Dönüşümlü Online UPS
AşamaTek Fazlı Giriş Tek Fazlı Çıkış
Şebeke GirişiKablolamaL / N + PE
Anma gerilimi208/220/230/240Vac
Voltaj Aralığı 110 ~ 285 VAC
Frekans aralığı40Hz ~ 70Hz
Giriş Güç Faktörü≥0,99
AC ÇıkışıKablolamaL / N + PE
Çıkış Voltajı208/220/230 / 240VAC
Voltaj Regülasyonu±1%
Çıkış Frekansı50/60±4Hz (Senkronizasyon Modu) / 50/60Hz±0.1% (Serbest Çalışma)
Dalga biçimiSaf Sinüs Dalgası
Bozulma
(THDV%)
<2%(Linear Load)
<7%(None-Linear Load)
Aşırı yük kapasitesi% 10Min@105 ~% 125 Nominal Yük
60Sec.@125%~150%Rated Load
0.5Sec.@>150%Rated Load
RandımanÇizgi modu>93%
Pil Modu>91%
Pil
&
Charge
Nominal Akü Voltajı144/192VDC
Internal/
192 / 240VDC
External
192VDC (192VDC)
Internal
192 / 240VDC
External
Pil Kapasitesi12V / 7AHx12 Adet
/
12V/7AHx16Pcs
Harici Batarya Bağlıdır 12V / 7AHx16 Adet
/
12V/9AHx16Pcs
Harici Batarya Bağlıdır
Yedekleme Süresi>6 dakika @ Yarım Yük>6 dakika @ Yarım Yük
Şarj AkımıDahili Bataryalı Standart Model: 1A
Long Backup Time Model :4A
FizikselŞasi StiliKule
Kule Ölçüsü C6KS: 190 (G) X318 (Y) x366 (D) mm,  C10kS: 190 (G) X340 (Y) x534 (D) mm
C6K-12BAT:190(W)X360(H)x534(D)mm
 C6K-16BAT, C10K: 190(W)X456(H)x534(D)
Ağırlık (kg)C6K-12BAT: 37kg
C6K-16BAT: 46.5kg
9,1kgC10K-7AHx16: 47,8 kg
C10K-9AHx16: 54.2kg
13,6kg
HMILCD EKRANGiriş Şebeke Voltajı, Frekans, Yük seviyesi, Çalışma Modu, Sağlık Durumu
Standart
Communication Interface
1 、 RS232 BAĞLANTI NOKTASI
Opsiyonel Genişletme Kartı  2 、 EPO / ROO Bağlantı Noktası  3 、 Akıllı Yuva  4 、 USB Kartı (HID değil)
  5、 NetWork Card:  Support SNMP/TCP/IP for remote monitoring the UPS via Smart Phone APP, Web page,  PC Monitor Software , Support Server / NAS shutdown
  6、CMC MODBUS Card,   7、AS400 Relay Card
Çalışma Ortamı
Endurance
Sıcaklık aralığı-10 ~ 50 °C
Bağıl nem% 0-98 (Yoğuşmasız)
Akustik Gürültü<55dB @ 1 meters


İLETİŞİME GEÇİN

E-posta Adresi*
Ad
Telefon numarası
Şirket Adı
İleti*

    Ücretsiz fiyat teklifi almak

    Temsilcimiz en kısa sürede sizinle iletişime geçecektir.
    Ad
    Cep
    E-posta
    İleti
    0/1000

    ilgili arama

    Wechat