Model : 1K / 1KS / 2K / 2KS / 3K / 3KS

 

Model : 6K / 6KS / 10K / 10KS


  • Feature
  • Parameter
  • get in touch
  • downloads

Application


 

Introducing our robust UPS Tower, a cutting-edge power solution that ensures reliable and uninterrupted power supply to your critical equipment. This UPS Tower is crafted with precision and engineered to handle a diverse range of input voltages, making it a perfect fit for systems operating on AC 208V, AC 220V, and AC 240V.

Designed with versatility at its core, our UPS Tower boasts exceptional compatibility, allowing it to seamlessly integrate into various electrical systems. Whether you're operating in a 208V, 220V, or 240V environment, this UPS Tower provides a stable and continuous power source to keep your equipment running smoothly.

The wide voltage compatibility of our UPS Tower ensures maximum flexibility and reliability. No matter where you are located or what voltage standard your facility uses, our UPS Tower has the ability to adapt and provide the necessary power backup. This ensures that your critical equipment remains operational during power outages or voltage fluctuations, minimizing the risk of data loss or equipment damage.

 


Feature


  •  

 

Zero Transfer time:True Double Conversion Online UPS, Provide most comprehensive protect mission critical equipment from wide range power quality issues
DSP Digital Control Based:Advance DSP base digital control bring high performance of high input Power factor, low distortion , supply the load with perfect sine wave AC power supply
Ultra Wide Input Mains range:Strong compatible with ultra with electric environment, stay well with ultra wide range mains of  90V~300V, 40~70Hz ,dramatically reduce battery discharge , prolong battery life
Best Loading Capability:Up to 0.9 Output Power Factor, 50/60 Hz Automatically adapting, selectable voltage , perfectly match all kind of application
Genset Compatible:Capable of work with wide range of Genset, isolate fluctuation and noise from Genset , provide stable and clean power supply to the user equipment.
High Input power factor:Thanks to digital controlled  PFC Technology, >0.99 input power factor, effectively avoid power pollution , save energy expense for customer
Reliable design:Made with strong Glass fiber base (FR4) double side PCB, company with large span component, greatly improve reliability in harsh environment, Well designed ventilation and conformal coating , avoid dust accumulation ,improve resistant to corrosion
Open to customization:Based on powerful controller and open architecture, the product is able to be customized to match need of integration of automatic system or intelligent supervisory system

 

FAQ


 

Do you have charging solution? 
A:Yes, BVT suitable for battery charging usage. In this application, our rectifier system is widely used for N+1 power supply and battery charging system management.

Does the product support the SNMP function?
A:Yes, 90% BVT product support SNMP. And all product built-in RS485 communication for standard. 

What is RS485?
A:RS485 is a communication interface, support real-time data communication function, and can use the monitoring software to monitor and control the working condition of the inverter power supply in a real-time manner. supply.(Optional)

Can the inverter adapt to high temperature and operate stably?
A:BVT supports a maximum temperature of -20℃~60℃, and the stable operation is unchanged. If you configure air conditioning cooling in a high temperature environment, the product life will be increased

Can the inverter power supply be used on the plane?
A:Currently not supported, because the height problem will affect the operation of the inverter and fail. Haibo ≥ 2000 meters, the inverter will fail and not work

How about the inverter load?
A:Super overload capacity, can withstand full load startup, with bypass switch, can switch to bypass power supply when overloaded

How about high frequency inverter power supply noise?
A:≤55dB

Can I choose the mains mode for my inverter power supply?
A:Yes, BVT inverter support AC main power supply and DC main power supply, 2 modes can be selected flexibly, and the mode can be changed through the LCD panel or the communication background software

What will causes Power failure and what can be done to resolve?
A: Check whether the positive and negative poles are reversed, and reconnect after confirming. If it cannot be turned on, please return the power supply back to BVT for inspection & repairing

What are the protection functions of the inverter power supply?
A:Input under-voltage protection, anti-DC input reverse connection, buffer protection, over-voltage protection, overload protection, short-circuit protection, over-temperature protection, temperature-controlled fan, etc.

 


Parameter table



Tower 1~3K Online UPS Datasheet(220V PF0.9 IEC62040)

 

Model 1K 1KS 2K 2KS 3K 3KS
Capacity VA/W 1kVA/900W 2kVA/1.8kW 3kVA/2.7kW
Topology Double Conversion Online UPS
Phase Single Phase Input Single Phase Output
Mains Input Wiring L/N+PE
Rated Voltage 208/220/230/240VAC
Voltage Range  90~300VAC
Frequency Range 40Hz~70Hz
Input Power Factor ≥0.99
AC Output Wiring L/N+PE
Output Voltage 208/220/230/240VAC
Voltage Regulation ±1%
Output Frequency 50/60±4Hz(Sync Mode) / 50/60Hz±0.1%(Free Run)
Waveform Pure Sine Wave
Distortion
(THDV%)
<2%(Linear Load)
<7%(None-Linear Load)
Over load
 capability
1Min@105%~125%Rated Load
30Sec.@125%~150%Rated Load
0.5Sec.@>150%Rated Load
Efficiency Line mode 88% 89% 90%
Battery Mode 86% 87% 88%
Battery
&
Charge
Rated Battery Voltage ① 24VDC
Internal
36VDC
External
48VDC
Internal
72VDC
External
72VDC
Internal
72VDC
External
Battery Capacity 7AHx2pcs External Battery Depends  7AHx4pcs External Battery Depends  7AHx6pcs External Battery Depends
Backup Time >6mins @ Half Load >6mins @ Half Load >6mins @ Half Load
Charging Current Standard Model with Internal Battery:1A
Long Backup Time Model :4A
Optional Configuration to Order
  1. External Battery Module Connector for Standards Model
  2. Battery Capacity 7AH/9AH
  3. Battery Quantity(2/4/6pcs) or (3/6/6pcs)
Physical Chassis Style Tower
Tower Dimension 1KS, 1K: 145(W)X220(H)x318(D)mm
 2KS, 2K, 3K, 3KS: 190(W) x 318(H) x 368(D)mm
Weight (kg) 8.4 4.7 16.2 10.5 21.2 12.0
HMI LCD DISPLAY Input Mains Voltage, Frequency, Load level, Operation Mode, Health Status
Standards
Communication Interface
1.RS232 PORT  2.EPO / ROO Port  3.Intelligent Slot  4.USB Card (not HID)
Optional Extension Card
  1. NetWork Card:  Support SNMP/TCP/IP for remote monitoring the UPS via Smart Phone APP, Web page,  PC Monitor Software , Support Server / NAS shutdown
  2. RS485-MODBUS Card,  LAN(TCP IP)-MODBUS Card,
  3. Mini AS400 Relay Card  
Operating Environment
Endurance
Temperature range -10~50oC
Relative Humidity 0-98%(Non-condensing)
Acoustics Noise <55dB @ 1 meters


Tower 6~10K Online UPS Datasheet(220V PF0.9 IEC62040)

 

Model 6K 6KS 10K 10KS
Capacity VA/W 6kVA/5.4kW 10kVA/9kW
Topology Double Conversion Online UPS
Phase Single Phase Input Single Phase Output
Mains Input Wiring L/N+PE
Rated Voltage 208/220/230/240Vac
Voltage Range  110~285VAC
Frequency Range 40Hz~70Hz
Input Power Factor ≥0.99
AC Output Wiring L/N+PE
Output Voltage 208/220/230/240VAC
Voltage Regulation ±1%
Output Frequency 50/60±4Hz(Sync Mode) / 50/60Hz±0.1%(Free Run)
Waveform Pure Sine Wave
Distortion
(THDV%)
<2%(Linear Load)
<7%(None-Linear Load)
Over load capability 10Min@105%~125%Rated Load
60Sec.@125%~150%Rated Load
0.5Sec.@>150%Rated Load
Efficiency Line mode >93%
Battery Mode >91%
Battery
&
Charge
Rated Battery Voltage 144/192VDC
Internal/
192/240VDC
External
192VDC
Internal
192/240VDC
External
Battery Capacity 12V/7AHx12Pcs
/
12V/7AHx16Pcs
External Battery Depends  12V/7AHx16Pcs
/
12V/9AHx16Pcs
External Battery Depends
Backup Time >6mins @ Half Load >6mins @ Half Load
Charging Current Standard Model with Internal Battery:1A
Long Backup Time Model :4A
Physical Chassis Style Tower
Tower Dimension  C6KS:190(W)X318(H)x366(D)mm,  C10kS: 190(W)X340(H)x534(D)mm
C6K-12BAT:190(W)X360(H)x534(D)mm
 C6K-16BAT, C10K: 190(W)X456(H)x534(D)
Weight (kg) C6K-12BAT: 37kg
C6K-16BAT: 46.5kg
9.1kg C10K-7AHx16: 47.8kg
C10K-9AHx16: 54.2kg
13.6kg
HMI LCD DISPLAY Input Mains Voltage, Frequency, Load level, Operation Mode, Health Status
Standards
Communication Interface
1、RS232 PORT
Optional Extension Card   2、EPO / ROO Port  3、Intelligent Slot  4、USB Card (not HID)
  5、 NetWork Card:  Support SNMP/TCP/IP for remote monitoring the UPS via Smart Phone APP, Web page,  PC Monitor Software , Support Server / NAS shutdown
  6、CMC MODBUS Card,   7、AS400 Relay Card
Operating Environment
Endurance
Temperature range -10~50oC
Relative Humidity 0-98%(Non-condensing)
Acoustics Noise <55dB @ 1 meters