DC-AC Inverter System 220Vdc to 220Vac

N+1 design
Effi>90%
STS Bypass transfer time<4ms
  • Feature
  • Parameter
  • get in touch
  • downloads
  1. Redundant design facilitates power output expansion

  2. Parallel design, easy maintenance and replacement, uninterrupted operation

  3. High-efficiency inverter conversion90%Energy-saving and environmentally friendly

  4. High protection level, reliable performance in harsh environments

  5. Intelligent control system enables remote monitoring and improves operational efficiency.

  6. RS485Communication interface, optionalRS485,SNMPRemote communication

  7. It can operate in both single-phase and three-phase modes and is suitable for power supply 

  8. 机柜海报素材_04.png

机柜海报素材_02.png

机柜海报素材_03.png


GeneralFull capacityDC220V 12KVADC220V 90KVADC110V 54KVA
System phase numberSingle-phase/Three-phase
Parallel functionSupport parallel operation
System maintenance bypassSupport (optional)
Rated power9.6KW72KW43.2KW
Module modelBWT220/220-3KVAMLBWT220/220-10KVASBWT110/220-6KVAS
Module capacity3KVA3KVA3KVA
Number of modules499
Module efficiency90%
Hot pluggingyesyesyes
Module power factor0.80.80.8
Module size9.5"/2U19"/2U19"/2U
DC InputDC input voltage220Vdc220Vdc110Vdc
DC voltage range48Vdc@Turn-off voltage ≤40Vdc,or ≥60Vdc,Power-on voltage: 42Vdc~59Vdc;220Vdc@Turn-off voltage ≤180Vdc,or ≥275Vdc,Power-on voltage:190Vdc~270Vdc
Battery TypeLithium batteries, lead-acid batteries, gel batteries, nickel-cadmium batteries
AC bypass inputBypass typeStatic switch
Voltage range176~264Vac
Frequency range40Hz~55Hz@50Hz
AC OutputOutput voltage220Vac/230Vac
Output frequency50Hz
Parallel Uneven Flow<3% of the effective value of the rated current
waveformPure sine wave(Resistance at full load <3%Nonlinear load <5%)
Dynamic responseVoltage transient range <3%Transient response recovery time≤60ms(load from) 0arrive 100)
Overload capacity105%~125%Continuous operation of the load 10min; 125%~150%Continuous operation of the load 60s
Inverter efficiency (80%(Resistive load)≥90%
Bypass moduleSTS
Bypass switching time≤4ms
Work environmentInsulation strength2000Vac/10mA/60s
humidity 0~90%,No condensation
Operating temperature-10℃~40℃
Working altitude(m)≤3000m,1500~ 3000m,Each increase in altitude100Meters, output reduction1%
noise(1m)<65dB
 IPgradeIP20
Cabinet dimensions42U/45U/48U
power distributioncustom made
Cooling methodcustom made
Monitoring showsPower supply is normal, inverter is normal, battery is undervoltage and output is abnormal, overload, etc.
Communication interfaceRS485, SNMP(Optional)